INS-ZSACC
Standalone code lock and proximity key reader
2mm thick flat front panel and brushed stainless steel buttons
111 x 240
Mounting box 90x220x31
Optionally – Surface mounting box
“INS-P-XS NT” (INS-ZSACC) 113x242x(37,5/29)
flush mounted
surface-mounted (additional mounting box INS-P-XS NT (INS-ZSACC))
2 wires for power supply, 2 wires for door opener
12 – 15VDC / 40 mA (without electric door strike)
~1,2W
2 x screw connectors for INS-ZS module:
– connection of a traditional electric strike (max. 1A) or connection of a reversing electric strike (max.0,5A) or CDN-PK relay module (contact load capacity max. 5A)
2 x screw connectors for INS-ACC module:
– connection of a traditional electric strike (max. 1A) or connection of a reversing electric strike (max.0.5A) or CDN-PK relay module (contact load max. 5A)
2 x ARK:
– power supply connection: “+DC” and “-DC” to the INS-ZS module
1 x screw connector ARK: “GND”
1 x screw connector ARK: “INPUT” to INS-ZS module
1 x screw connection ARK: “INPUT” to INS-ACC
– connection of NO contact e.g. bell button – direct activation of the output (activated by shorting to GND)
– resistant to weather conditions and acts of vandalism
– operating temperature: from -20 to 50ºC
– can be surface mounted after purchasing the INS-P-XXS NT (INS-ZSACC) box
– 255 individual 4-digit opening codes
– Compatible with ACO code tables
– Standard for reading proximity tags: Unique 125 kHz
– Supports max. 1536 key fobs or cards
– up to 4 independent outputs – depending on configuration
– audible signaling (can be switched off)
– output time adjustment from 1s – 9s.
– option to connect various types of electric strikes (traditional, reversing, with memory) or electromagnetic locks (CDN-PK module required)
CDN-PK module required)
– support for two independent external push buttons: INPUT (e.g. INS-OB )
– programming from the device level (adding keyfobs by means of master keyfob, without dismantling the device).
– Computer programming (using optional CDN-USB cable).
– Common PC software for proximity reader support in INS-ACC, CDNP6ACC, CDN-ACC, xNACC and xNPACC products
– free software
– wide range of supply voltage